info@tuncmatik.comTrue double conversion online technology
Online UPSs are the most suitable choice, especially for computers and other sensitive devices. These types of UPSs completely isolate your sensitive devices from the network, charge their batteries with electricity from the network, and feed your connected sensitive devices with the help of various filters. As a result, all unwanted situations that may occur in the network are filtered by the online UPS and your sensitive devices are fed with clean energy.
Everything is under control with the multifunctional, easy-to-read LCD screen. Thanks to the new advanced LCD screen, functions, input-output values and alarms can be easily monitored.
Rated voltage | 200 / 208 / 220 / 230 / 240 VAC |
Voltage range Low voltage transfer | 160 VAC ±5% at 100%-80% load, 140 VAC ±5% at 80%-70% load, 120 VAC ±5% at 70%-60% load, 110 VAC ±5% at 60%-0% load , (<35°C) |
Voltage range Low voltage correction | 175 VAC ±5% at 100%-80% load, 155 VAC ±5% at 80%-70% load, 135 VAC ±5% at 70%-60% load, 125 VAC ±5% at 60%-0% load , (<35°C) |
Voltage range High voltage transfer | 300 VAC ± 5% |
Voltage range High voltage correction | 290 VAC ± 5% |
Frequency range | 40 Hz ~ 70 Hz |
Power factor | 0.990 at 100% load (Rated input voltage) |
Bypass voltage range | Bypass high voltage point on models with 200/208/220/230/240 VAC output |
Bypass voltage range | Bypass low voltage point on models with 200/208/220/230/240 VAC output |
Phase | One phase + Earth |
Output voltage | 200 / 208 / 220 / 230 / 240 VAC |
Output power factor (PF) | 1 |
AC voltage regulation (Battery mode) | ±%1 |
Frequency range (Synchronous mode) | 47 Hz ~ 53 Hz or 57 Hz ~ 63 Hz |
Frequency range (Battery mode) | 50 Hz or 60 Hz ± 0.1 Hz |
Overload Grid Mode | %105-110 by-pass after 10 minutes, 110-130% by-pass after 1 minute, 130-150% by-pass after 3 seconds |
Overload Battery Mode | %105-110 by-pass after 1 minute, >%110 by-pass after 3 seconds |
Current peak ratio (Crest factor) | 3/1 max. |
Harmonic distortion | ≤3% THD (linear load) ≤6% THD (non-linear load) |
Transfer time Network <-> Battery mode | 0 ms |
Transfer time Inverter <-> bypass | 4 ms (typical) |
Waveform (Battery mode) | Full sine wave |
Output socket | 2 x Schuko |
Network mode | ~88% |
Battery mode | ~83% |
Battery type | 12V9AH |
Number of batteries | 2 |
Support period | Depends on battery capacity |
Charging voltage | 27.4 VDC ± 1% |
Charging current | 1A |
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge counter, Error status |
Alarm | Mains error, Low battery, Overload, System error |
D x W x H (mm) | 293 x 144 x 209 |
Net weight (kg) | 8.9 |
Operating temperature | 0-40°C |
Humidity | 20-90% relative humidity (non-condensing) |
Noise level | < 50 dBA from 1 meter |
Smart RS-232 or USB | Windows 98/2000/2003/XP/Vista/2008, Windows 7/8, Linux, MAC |
SNMP (Optional) | Power management with SNMP manager and web browser |