Rated Voltage 380/400/415Vac, (3Ph+N+PE)
Input Voltage Range 305~478Vac (Full Load); 208~478Vac (50% Load)
Frequency 40-70Hz
Power Factor 0.99
Harmonic Distortion (THDi) ≤3% (100% linear load)
Bypass Voltage Range 220Vac Max. Voltage +25%(optional +10%,+15%,+20% ); 230Vac Max. Voltage +20%(optional +10%,+15%) ; 240Vac Max. Voltage +15%(optional +10%) ; Min. voltage -45% (optional -20%,-30%)
Bypass Synchronization ±1%/±2%/±4%/±5%/±10% optional (default
Generator Input Supports
EXIT
Power factor 1.0
Rated AC Voltage 380/400/415Vac, (3Ph+N+PE)
Voltage Regulation ±1%
Sudden Voltage Response ±5% (linear load)
Frequency 1.Sync with Network Mode input; When the input frequency is >±10% (±1%/±2%/±4%/±5% optional), the output is (50/60±0.1%)Hz.; 2.Battery Mode
Crest factor 3/1
Harmonic distortion (THD) < 2% (linear load), <5% (non-linear load)
Overload Capacity AC Mode Load 110% last 60 minutes to bypass, ≤125% last 10 minutes to bypass, ≤150% last 1 minute to bypass,>150% immediate bypass; Battery Mode Load 110% last 10 minutes, ≤ 125% last 1 minute, ≤ 150% last 5s, > 150% turns off UPS immediately.
Efficiency (Normal mode) Up to 94.5%
Transfer Time Grid to Battery
BATTERY
Battery Voltage Standard Device ±120Vdc (3x20 Pieces 12V9AH); Long Support Time 10-30kVA ±96/108/120Vdc; (16 ~ 20 Batteries, 16 Defined, Standard Units and 20 No power reduction; 18 output power factor 0.8 / 0.9; 16 output power factor 0.7 / 0.8;) 40kVA / 10-30kVA (Opt.)±180 /192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs Option.)
Charging Current (Charging current can be adjusted according to battery capacity) Standard device 4.05A; Long support time model Max. Current 20A (limited by input current)
SYSTEM FEATURES
Alarms Overload, mains abnormal, UPS error, battery low, etc.
Protection short circuit, overload, over temperature, low battery, fan error alarm.
Communication Interfaces USB, RS232,RS485, Parallel port, Dry contact, Intelligent slot, SNMP card (optional), Relay card (optional), Battery temperature sensor (optional)
ENVIRONMENTAL
Operating Temperature 0℃~40℃
Storage Temperature -25℃~55℃(without battery)
Humidity 0~95% non-condensing
Acoustic Noise (from 1M distance) <64dB
Altitude <1500m. > When 1500m, reduce the rated power for use
DIMENSIONS & WEIGHT
Dimension Width×Length×Height (mm) Standard device:250×900×868; Long support period model 250×580×655
Net weight (Kg) 239/46
STANDARDS
Security Certificates IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8